Liquids Fuel Tank Non Contact Ultrasonic Level Sensor
Application:
The series is an compact 2-wire series ultrasonic level meter for continuous non-contact level measurement in liquids and solids. It consists of probe and electronic units, both of which are leak-proof structure. This series can be widely applied to the metallurgical, chemical, electricity and oil industries.Features:
Continuous non-contact level measurement with compact version;- Integrated design, installed conveniently;
- Protected in the excessive voltage and current , protected in the thunder and lightning;
- The big show window of LCD or LED is easy to debug and observe;
- Excellent anti-interference capability;
- 4-20mA output;
- Intellectual signal treatment technology, guarantee that the instrument meets various kinds of operating occasion
- All metal outer cover ( IP67 ), airproof and alkali-resisting, meet the abominable environment.
Structure:
The series is consists of sensor and electronic unit.Measuring principle: Time-of-flight method
The sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The meter measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound c) to calculate the distance D between the sensor membrane and the product surface: D = c •t/2 . As the device knows the empty distance H from a user entry, it can calculate the level as follows: L = H - D .Blanking distance : Span F may not extend into the blanking distance B. Level echo from the blanking distance cannot be evaluated due to the transient characteristics of the sensor.
Technical data:
1.Basic data
Type | MLT |
Power supply | DC24V (±10%) 60mA |
Display | 4 digit LCD |
Accuracy | 0.2% of full span (in air) |
Output current | 4-20mA |
Output load | 0-500 |
Temperature range | -40ºC~80ºC |
Pressure range | ±0.1MP (press definitely) |
Measure cycle | 1 second (changeable ) |
Beam angle | 8º(3db) for range :4m 6m 8m 5º(3db) for range :12m 15m 20m 30m |
Parameter set up | 3 induction buttons |
Cable connection | PG13.5 |
Material | The electronic unit : metal The sensor: ABS |
Protect grade | IP67 |
Fix | Screw or Flange |
2.The measuring range:
MODEL | MLT4 | MLT6 | MLT8 | MLT12 | MLT15 | MLT20 | MLT30 |
LIQUID | 4.00m | 6.00m | 8.00m | 12.00m | 15.00m | 20.00m | 30.00m |
SOLID | 3.00m | 5.00m | 7.00m | 10.00m | 15.00m |
3.The blacking distance:
MODEL | MLT4 | MLT6 | MLT8 | MLT12 | MLT15 | MLT20 | MLT30 |
Blacking distance | 0.20m | 0.25m | 0.30m | 0.45m | 0.60m | 0.80m | 1.20m |